Multi-core hydraulic observation YSPT-4 type hydraulic cable four-core shielded cable
+
  • Multi-core hydraulic observation YSPT-4 type hydraulic cable four-core shielded cable

Multi-core hydraulic observation YSPT-4 type hydraulic cable four-core shielded cable

YSPT hydraulic cable specifications and models are suitable for the signal transmission line between YSPT hydraulic cable specifications and models sensors and observation instruments in the operation observation system of dams, bridge piers, roadbeds of high-speed railways and other buildings.

Still hesitating? Get samples,Contact Us!

Classification

Keyword

  • Description
  • 1. YSPT hydraulic cable specifications and models are suitable for the signal transmission line between YSPT hydraulic cable specifications and models sensors and observation instruments in the operation observation system of dams, bridge piers, roadbeds of high-speed railways and other buildings.

    2, product characteristics: oil resistance: very good chemical resistance: acid, alkali, solvent and various hydraulic oil performance excellent weather resistance: UV resistance, sunlight aging performance is excellent, suitable for outdoor use halogen-free, environmental protection, hydrolysis resistance, corrosion resistance, oil resistance, low temperature flexibility, low temperature resistance, wear resistance, aging resistance, antifungal, etc

    3, YSPT hydraulic cable applicable life: harsh environment use more than twenty-five years, high mechanical strength temperature range:-40 ℃ ~ 90 ℃

    4. Product application: YSPT hydraulic observation cable is suitable for outdoor mobile hydraulic observation instruments and other similar electronic devices. The hydraulic observation cable has good waterproof performance and electrical performance, and can be directly buried in concrete or rock and soil for a long time, and placed in the river, lake or seawater with pressure range for a long time. The hydraulic observation cable has good acid and alkali resistance, electromagnetic interference resistance and lightning protection. 5. Applicable engineering: Its products have been widely used in the measurement of physical quantities in the fields of hydropower, railways, highways, mines, national defense and construction engineering safety monitoring, with high reliability and adaptability to harsh environments. The models are: YSPT-2A, YSPT-2, YSPT-4A, YSPT-4, YSPT-8, YSPT-10, YSPT-14, etc.

    6. Technical requirements:

    6.1 conductor core and grounding wire are made of tinned copper single wire stranded into a bundle, its performance and appearance should be in accordance with the provisions of GB4910, tinned copper wire bundle pitch ratio should not be greater than 25 times.

    The 6.2 insulation layer shall be a mixture of high-pressure polyethylene and color masterbatch. The insulation layer shall be tightly packed on the conductor and easy to peel off without damaging the conductor. The insulation core shall be divided into four cores (white, green, red and black cores (white and green). The insulated wire core shall be twisted together with the ground wire to form a cable after shielding, and the pitch ratio of the cable shall not be more than 14 times.

    The 6.3 outer sheath shall be tightly packed on the stranded cable core and easily stripped without damaging the insulated core. The surface of the outer sheath shall be flat, smooth, uniform in color and without mechanical damage.

    6.4 The finished cable should be able to withstand the AC rated voltage of 2000V test, 5 minutes without breakdown. The insulated wire resistance between each wire core of finished cable and ground wire shall not be less than 50MQ · KM. The finished cable shall be able to withstand water pressure test. Under the condition of room temperature and water pressure of 1MPa, the measured value of insulated wire resistance shall not decrease after being pressed for 168 hours.

    7. Specifications and parameters of hydraulic observation cable

    Model Core wire x section m2 Conductor structure root/diameter mm Insulation outer diameter Outer diameter of sheath DC resistance
    Core wire Lightning protection ground wire mm mm Ω/km
    YSPT-14 14x0.35 1x0.3 7/0.25 6/0.25 1. 55 ≈ 11.0 ≈ 50
    YSPT-10 10x0.35 1x0.3 7/0.25 6/0.25 1. 55 ≈ 10.2 ≈ 50
    YSPT-4 4x0. 40 1x0.35 8/0.25 7/0.25 1.6 ≈ 7.4 ≈ 45
    YSPT-4A 4x0.35 1x0.3 7/0.25 6/0.25 1. 55 ≈ 6.2 ≈ 50
    YSPT-4P 4x0.40 1x0.35 8/0.25 7/0.25 1.6 ≈ 7.4 ≈ 45
    YSPT-4Q 4x0. 40 1x0.35 8/0.25 7/0.25 1.6 ≈ 8.1 ≈ 45
    YSPT-2 2x0. 50 1x0.4 10/0. 25 8/0.25 1. 9 ≈ 7.1 ≈40
    YSSX-5 5x0.75 15/0.25   2.1 ≈ 8.2 ≈ 50

     